ZUMLINK-DIN-20A-SW
The Zūm® wired ZUMLINK-DIN-20A-SW provides zero cross switching for high in rush lighting loads. The device can be wired to other in-room Zūm devices to provide load control. Energy-saving options are available to enable daylighting, occupancy or vacancy sensing, and centralized monitoring and management. Room setup can be accomplished quickly through the Zūm app.
Zūm Link Wired Technology
Zūm Link technology enables in-room lighting control through keypads and sensors wired to controllers. Zūm Wired devices connect via CBL-CAT5E-ZUMLINK-P CAT5e cable (sold separately) to RJ-45 ports to provide simple daisy-chaining and lighting control of compatible loads. The Zūm Wired devices work together in a local ecosystem to provide customized solutions using the Zūm app.
Energy Efficiency
Occupancy sensor, vacancy sensor, and daylight sensor connectivity enables significant energy savings. To reduce energy usage, lights turn off automatically when the room is vacant and dim gradually depending on the amount of natural daylight in the room.
DIN Rail Mounting
DIN rail Zūm devices snap onto a standard DIN rail for installation in a wall mount enclosure (Crestron DIN-EN series or similar) or on a wall panel.
Override Contact Closure Input
An integrated contact closure provides the means to place all connected Zūm Net and Zūm Link devices into Emergency Override mode.
Specifications
Load Control
Line Voltage 100-277VAC, 50/60 Hz
Switch Load Types LED, electronic drivers, incandescent, magnetic low-voltage, electronic lowvoltage,neon/cold cathode, high-intensity discharge, small motor loads
Switch Rating 20A 100-277VAC, 50/60 Hz resistive; 1 HP @ 120-277VAC
Switch Lifetime General Rating: 100,000 on/off operations, 16A @ 277VAC; Motor Rating: 100,000 on/off operations, 1HP @ 120/230/277VAC; Resistive Rating: 30,000 on/off operations, 20A @ 277VAC
Zūm Link Power Bus Requirements
Max Current Consumption 50mA Without sensor terminal.
Max Allowable Sensor Terminal Current 85mA Passthrough from Zūm Link bus
Wired Communications
ZUMLINK (2) RJ-45 ports; In-room Zūm Link device daisy-chaining
24V, OCC, GND Occupancy sensor input; Spring clamp connector; Each terminal accepts one 20-24 AWG solid wire
24V, PHO, GND Photo sensor input; Spring clamp connector; Each terminal accepts one 20-24 AWG solid wire
OVR, GND Override control input; Spring clamp connector: Each terminal accepts one 20-24 AWG solid wire
Controls and Indicators
TEST (1) Pushbutton and (1) green LED; Push to toggle the switched load output on and off; Press and hold to cycle the dimming level up and down; LED indicates that the load is turned on; LED lights and flashes during room setup and factory reset
ZUMLINK Status (1) bi-color green/red LED; LED lights green in normal operation; LED lights red when a fault is detected
Connections
N, L, SW (Neutral, Line, Switch) (1) 3-pin terminal block; Each terminal accepts one 12-24 AWG wire
Environmental
Local InCabinet Air Temperature 32° to 122°F (0° to 50°C)
Humidity 10% to 90% RH (noncondensing)
Heat Dissipation 4 BTU/hr @ 0A; 14 BTU/hr @ 20A
Construction
Light gray polycarbonate housing with polycarbonate label overlay, 53 mm DIN rail mount, occupies 3M module spaces, DIN 43380 for factor for enclosures with 45 mm front panel cutout
Dimensions
Height 3.69 in. (94 mm)
Width 2.08 in. (53 mm)
Depth 2.32 in. (59 mm)
Weight 4 oz (133 g)
Compliance
Regulatory Model: M202231002
Intertek® Listed for US & Canada, CE, FCC Part 15 Class B, IC, WEEE
Model
ZUMLINK-DIN-20A-SW
DIN Rail Load Controller, High Inrush Switch, 20A, 100-277V for Zūm® Lighting Control with Link Communication